Uhlelo lwebhethri ye-lithium iron phosphate ebekwe odongeni/ephansi eyethulwe i-Huijue Group isebenzisa amaseli e-LiFePO₄ aphephile kakhulu, anobungani bemvelo, aqukethe impilo yomjikelezo omude kanye nokuminyana kwamandla okuvelele, futhi isetshenziswa kabanzi kuzimo zokugcina amandla njengemizi, amabhizinisi, nama-microgrid.
Thumela Message Thola Intengo
| Imodeli yomkhiqizo | HJ-HBL48101W(B-5) |
| Voltage Kulinganiselwe ngo- | 51.2V |
| Ikhono elilinganisiwe | 100Ah |
| Kukalwe Amandla | 5.12kWh |
| Ukukhipha Ububanzi Bokulinganisa | 43.2V ~ 58.4V |
| I-Voltage yokushaja | 57.6 ~ 58.4V |
| Sika-off Amandla | 43.2V |
| I-Max.Ukushaja Kwamanje | 100A |
| Okunconyiwe Ukushaja Kwamanje | 50A |
| I-Max.Yamanje Yokukhipha | 100A |
| Ukuphumelela | 98% |
| Ubukhulu H*W*D(mm) | 550 * 370 * 185 |
| I-Carton Dimension,H*W*D(mm) | 630 * 460 * 235 |
| Isisindo esincane (kg) | 45 |
| Isisindo Esiphelele (kg) | 47 |
| Umswakama | 5% ~ 95% Umswakama ohlobene |
| Ukushaja Ubushushu | -20 ℃ ~ 65 ℃ |
| Ikhipha Izinga Lokushisa | -20 ℃ ~ 60 ℃ |
| Isitoreji Temperature | -10 ℃ ~ 50 ℃ |
| I-Cycle Life | >6000times(0.2℃,@25℃,80%DOD) |
| Design Life | > Iminyaka engama-10 |
| Imodi yokusebenza | Isikrini Esithintekayo |
Qaphela: Ukucaciswa kungashintsha ngaphandle kwesaziso sangaphambili sokuthuthukiswa komkhiqizo. Ishidi le-data
Isebenzisa amaseli ebhethri e-lithium iron phosphate ekhwalithi ephezulu, aqinisekiswe izindinganiso zokuphepha zamazwe ngamazwe okuhlanganisa i-MSDS, UN38.3, ROHS, IEC62619, ne-UL, enempilo yomjikelezo engaphezu kwemijikelezo engu-6,000.
Ifaka i-BMS ehlakaniphile edidiyelwe eqapha amandla kagesi eseli ngalinye, isimanje, kanye nezinga lokushisa, futhi ihlanganisa ukushajwa ngokweqile, ukuchithwa ngokweqile, i-overcurrent, ukuvikelwa kwezinga lokushisa, nemisebenzi yokulinganisa esebenzayo ukuze kuqinisekiswe ukufana kweseli nempilo eyandisiwe yesevisi.
Isekela amamojula webhethri afika kwangu-16 ngokuhambisana ukuze akhule, avumelane nezimo ezivumelana nezimfuneko zamandla ahlukene kanye nomthamo.
Isakhiwo samandla aphansi esingenazo okudluliselwa ngaso, sifinyelela ukusetshenziswa kwamandla okubekwe eceleni njengeleveli ye-milliwatt, okuthuthukisa ukusebenza kahle kwawo wonke amandla.
Isixazululo sezimo ezahlukahlukene njengezindawo zokuhlala, ezohwebo, nezimboni, ukuqinisekisa ukusebenza okuzinzile kwemishini kanye nokusetshenziswa kwamandla ngendlela efanele.
Sizibophezele ekunikezeni ukwesekwa okusheshayo, okuchwepheshile ukuze siqinisekise ukuthi izidingo zakho zamandla zihlala zihlangatshezwana nezinga eliphezulu lesevisi.
Silapha ukuze siphendule imibuzo yakho futhi sikunikeze izixazululo zamandla ezifanelana kangcono nezidingo zakho.