Ikhaya / Imikhiqizo / Imikhiqizo Yokuxhumana / Isikhungo sedatha / Imodyuli Encane / Isikhungo Sedatha Ye-Micro Module Yezinga Lekhabhinethi le-HR1000
Isikhungo Sedatha Ye-Micro Module Yezinga Lekhabhinethi le-HR1000
Isikhungo Sedatha Ye-Micro Module Yezinga Lekhabhinethi le-HR1000

Isikhungo Sedatha Ye-Micro Module Yezinga Lekhabhinethi le-HR1000

I-J-net Rack HR1000 iyisisombululo sesikhungo sedatha se-micro-module esihlakaniphile sesizukulwane esilandelayo esihlanganisa ukusatshalaliswa kwamandla, i-UPS, ukuqapha, ukupholisa, izinhlelo zokuvikela umlilo, ukukhanyisa kanye namakhabhinethi. Ihlinzeka ngendawo yokusebenza enhle kakhulu engakaze ibonwe kanye neplatifomu yesiqinisekiso ethembekile yezimo zesicelo segumbi elincane nelincane le-IT.

  • Thayipha:  Imodyuli Encane

Thumela Message   Thola Intengo

Amapharamitha

Ithebula lokucushwa kwekhabhinethi elilodwa
Uhlelo lweKhabhinethi
Ubukhulu (Ububanzi x Ububanzi x Ububanzi MM) 2000(2200)X 600X 1350
Umthamo 42U(46U)
Isilinganiso Sokuvikelwa IP30
Operating Temperature -20 ℃ ~ 45 ℃
Ukufakwa Iphansi lekhonkrithi, iphansi eliphakanyisiwe
Umthwalo omkhulu ngekhabhinethi ngayinye 6KW
Izidingo zokuthwala ikhabhinethi ye-IT Umthwalo oqinile 1500kg, umthwalo oguquguqukayo 1000kg
Izinhlelo Zokukhiqiza Ukupholisa
Ukunikezwa kwamandla okufaka kwe-AC okulinganiselwe I-220V AC 50Hz
Umthamo wokupholisa (L35/L35) 3.5KW
Kukalwe amandla wokufaka 1270W
Kukalwe njengamanje 8A
Ukushisa amandla 1000W
I-Refrigerant R410A
Ukuzwela isilinganiso sokushisa ≥0.99
I-Energy Efficiency Ratio ≥3.2
Ukusatshalaliswa komoya Ukunikezwa komoya wangaphambili, ukubuya komoya wangemuva
Ukufakwa Ukugibela kwe-Rack
- Uhlelo Lokusabalalisa
Izinga lokuvikela umbani Iklasi C, Ku-20ka, Imax40ka
Ukungena kwamandla Iziteshi ezilodwa nezimbili ongazikhethela
Uhlelo Lokushintsha Amandla Amabili Ongakukhetha kokufaka okunezindlela ezimbili
Amandla we-UPS 6KVA / 10KVA
Ukwakhiwa kwe-UPS N,N+1,2N
Input Voltage Isigaba Esisodwa esingu-220V Isigaba Esithathu esingu-380V
Okukhipha voltage 220V~240V AC 50Hz
380V~400V AC 50Hz
Isici samandla okukhiphayo 0.9
Ukucushwa kwebhethri Amabhethri e-lithium afakwe erekhini, amakhabethe ebhethri le-lithium
Isikhathi sokulondoloza 15 ~ 30min
Lungisa i-bypass Standard
ЧИСЛЕННОСТЬ ОБУЧАЮЩИХСЯ И УЧИТЕЛЕЙ В ГОСУДАРСТВЕНЫХ И МУНИЦИПАЛЬНЫХ ОБЕЩЕОБРАЗЛ ОРГАНИЗАЦИЯХ
ЧИСЛЕННОСТЬ ОБУЧАЮЩИХСЯ И УЧИТЕЛЕЙ В ГОСУДАРСТВЕНЫХ И МУНИЦИПАЛЬНЫХ ОБЕЩЕОБРАЗЛ ОРГАНИЗАЦИЯХ Sekela ukufinyelela kwe-interface yewebhu ekude
I-interface yasendaweni Isikrini sokuthinta esijwayelekile esingu-10 intshi
I-O&M yeselula Uhlelo Lokusebenza Lweselula, Izaziso ze-SMS
Intuthu umtshina Akuphoqelekile
Ukucwiliswa emanzini Akuphoqelekile
Izinga lokushisa nomswakama Akuphoqelekile
ukukhiya umnyango Akuphoqelekile
Ukuqashwa kwevidiyo Akuphoqelekile

 

Ithebula lokulungiselela amakhabhinethi amaningi
Uhlelo lweKhabhinethi Izinhlelo Zokukhiqiza Ukupholisa
Ubukhulu (Ububanzi x Ububanzi x Ububanzi MM) 2000(2200)X 600X 1350 Ukunikezwa kwamandla okufaka kwe-AC okulinganiselwe I-220V AC 50Hz
Uhlobo lwamapayipi Amakhabethe amaningi Umthamo wokupholisa (L35/L35) 3.5KW*2
Inani lamakhabethe angawodwa Amayunithi we-2-3 Kukalwe amandla wokufaka 1270W * 2
Umthamo 42U (46U) * inani lamakhabethe Kukalwe njengamanje 8A
Isilinganiso Sokuvikelwa IP30 Ukushisa amandla 1000W * 2
Operating Temperature -20 ℃ ~ 45 ℃ I-Refrigerant R410A
Ukufakwa Iphansi lekhonkrithi, iphansi eliphakanyisiwe Ukuzwela isilinganiso sokushisa ≥0.99
Umthwalo omkhulu ngekhabhinethi ngayinye 6KW I-Energy Efficiency Ratio ≥3.2
Isekela ukusetshenziswa kwamandla okuphezulu komthwalo we-IT 10KW Ukusatshalaliswa komoya Ukunikezwa komoya wangaphambili, ukubuya komoya wangemuva
Izidingo zokuthwala ikhabhinethi ye-IT Umthwalo oqinile 1500kg, umthwalo oguquguqukayo 1000kg Ukufakwa Ukugibela kwe-Rack
- Uhlelo Lokusabalalisa ЧИСЛЕННОСТЬ ОБУЧАЮЩИХСЯ И УЧИТЕЛЕЙ В ГОСУДАРСТВЕНЫХ И МУНИЦИПАЛЬНЫХ ОБЕЩЕОБРАЗЛ ОРГАНИЗАЦИЯХ
Izinga lokuvikela umbani Iklasi C, Ku-20ka, Imax40ka ЧИСЛЕННОСТЬ ОБУЧАЮЩИХСЯ И УЧИТЕЛЕЙ В ГОСУДАРСТВЕНЫХ И МУНИЦИПАЛЬНЫХ ОБЕЩЕОБРАЗЛ ОРГАНИЗАЦИЯХ Sekela ukufinyelela kwe-interface yewebhu ekude
Ukungena kwamandla Iziteshi ezilodwa nezimbili ongazikhethela I-interface yasendaweni Isikrini sokuthinta esijwayelekile esingu-10 intshi
Uhlelo Lokushintsha Amandla Amabili Ongakukhetha kokufaka okunezindlela ezimbili I-O&M yeselula Uhlelo Lokusebenza Lweselula, Izaziso ze-SMS
Amandla we-UPS I-10KVA Intuthu umtshina Akuphoqelekile
Ukwakhiwa kwe-UPS N,N+1,2N Ukucwiliswa emanzini Akuphoqelekile
Input Voltage Isigaba Esisodwa esingu-220V Isigaba Esithathu esingu-380V Izinga lokushisa nomswakama Akuphoqelekile
Okukhipha voltage 220V~240V AC 50Hz
380V~400V AC 50Hz
ukukhiya umnyango Akuphoqelekile
Isici samandla okukhiphayo 0.9 Ukuqashwa kwevidiyo Akuphoqelekile
Isikhathi sokulondoloza 15 ~ 30min Uhlelo lokulwa nomlilo
Lungisa i-bypass Standard Izicisha-mlilo ze-rack Ukutholwa kwezinga lokushisa kanye nomshini wokucima umlilo ohlanganisa konke ndawonye

Qaphela: Imininingwane ingashintsha ngaphandle kwesaziso sangaphambilini sokuthuthukiswa komkhiqizo.

Isici

  • In-depth integration of data center infrastructure products in one cabinet, on-site installation is simply fixed, powered on, and construction time is only 4 hours

  • A single system is configured with a color touch screen, which can display all system parameters, monitoring information, alarm records, etc. locally

  • Network monitoring management, which can be connected to a third-party monitoring system to achieve unattended management of remote browsing monitoring

  • Rack-mounted air-conditioning system, saving air-conditioning cabinet installation space

  • Frequency conversion refrigeration technology, cold and hot channel isolation, PUE as low as 1.5

  • The welded frame can meet the requirements of a magnitude 9 earthquake

  • Compatible with dehumidification heating function to avoid the risk of condensation

  • Real-time monitoring of internal resistance, voltage and temperature of the battery, intelligent disconnection of overheating to prevent fire

  • Optional cabinet-level fire extinguishers to meet fire protection needs

Isicelo

Ilungele ukusetshenziswa kwe-scenar ios ehlukahlukene njengezakhiwo zokuhlala kanye nezakhiwo zamahhovisi ezentengiselwano

Bheka Ucwaningo Lwezifundo

Isixazululo

Telecom Solar Power Systems

Kusukela ezikhungweni zedatha eziyinhloko zasemadolobheni kuya ezifundeni ezikude, ezingaphandle kwegridi, izixazululo zamandla zesayithi le-Huijue zimboza uhla olubanzi lwezimo zohlelo lokusebenza eziyinkimbinkimbi emhlabeni jikelele.

Buka Ngini

Uhlelo Lwamandla Endawo Olujwayelekile

I-Standard Site Energy System iyithuluzi elihlanganisiwe nelihlakaniphile eliyinhloko lesistimu yamandla e-telecom, elisetshenziswa kabanzi eziteshini zeselula, ezikhungweni zedatha, nakwezinye izimo. Ihlanganisa ukunikezwa kwamandla, ukusatshalaliswa kwamandla, amandla okusekela, ukuvikelwa, kanye nokuqapha kuyunithi eyodwa, inikeza amandla kagesi e-48V DC azinzile futhi athembekile kanye nezinhlelo zebhethri zokusekela zemishini yokuxhumana. Ukuze ibhekane nenkinga yokuntuleka noma okunzima ukufinyelela igridi yeziteshi zesisekelo, futhi ngokuhambisana nomkhuba wenqubomgomo yokonga amandla nokunciphisa ukukhishwa, i-Huijue Group (HJ Group) yethule isixazululo samandla esiteshi sesisekelo esisha. Isixazululo sisebenzisa ubuchwepheshe obusha bamandla (ukugcina amandla omoya kanye nedizili) ukuze sinikeze isiqinisekiso esithembekile sokusebenza okuzinzile kweziteshi zesisekelo zokuxhumana. Ngokuhlanganisa imithombo yamandla avuselelekayo njengamandla omoya nokukhanya, nesistimu yokugcina amandla ehlakaniphile kanye nokukhiqizwa kwamandla edizili okusebenzayo kakhulu njengesengezo, kwakhiwa isethi yesistimu yokuhlinzeka ngamandla ezinzile, esebenza kahle futhi eluhlaza, engahlangabezana nesidingo samandla seziteshi zeselula futhi isize imboni yezokuxhumana ukuthi iqhubeke nokukhula ngokuzinzile endleleni yokonga amandla nokunciphisa ukukhishwa ngasikhathi sinye.

Buka Ngini

Isayithi Lokuxhumana Elincane

I-Compact Communication Site iyithuluzi elihlanganisiwe nelihlakaniphile eliyinhloko lesistimu yamandla ezokuxhumana, elisetshenziswa kabanzi eziteshini zeselula, ezikhungweni zedatha, nakwezinye izimo.

Buka Ngini

Isayithi Lokuxhumana Kwamandla Ahlanganisiwe

Ihlanganisa imishini yamandla ehlanganisa zonke izimo, okuhlanganisa izinsiza zamandla ezihlanganisiwe, ama-AC-DC converters, amabhokisi kagesi angaphandle e-5G, amakhabethe amandla ahlanganisiwe angaphakathi/angaphandle, kanye namakhabethe kagesi asekamelweni lemishini. Isekela ngokugcwele imithombo yamandla emisha efana ne-PV kanye namandla omoya, yakha uhlelo lokusabalalisa amandla oluhlanganisiwe lwe-"New Energy + Grid Power + Energy Storage".

Buka Ngini

Uhlelo Lokuphathwa Kwamandla Esayithi

Uhlelo Lokuphathwa Kwamandla Oluhlanganisiwe Lwesiteshi Se-Base Station luyisisombululo samandla aluhlaza esihlanganisiwe esenzelwe ngqo iziteshi zokuxhumana ngocingo; ngokuhlanganisa imithombo eminingi yamandla, ukuthunyelwa okuhlakaniphile, kanye nokuphathwa kokusebenza kahle kwamandla, kuqinisekisa ukusebenza kahle, okuzinzile, kanye nokusebenza kahle kokunikezwa kwamandla esiteshi sesisekelo.

Buka Ngini

I-I&C Energy Storage

Izixazululo zokugcina amandla ze-Huijue Group (HJ Group) (30 kWh kuya ku-30 ​​MWh) zimboza ukuphathwa kwezindleko, amandla okusekela, kanye nama-microgrid. Izixazululo zokugcina amandla ze-HuiJue Group zezentengiselwano nezezimboni zinikeza amandla asukela ku-30 ​​kWh kuya ku-30 ​​MWh. Lezi zixazululo zimboza izinhlelo zokusebenza eziningi zezentengiselwano, njengokuphathwa kwezindleko zikagesi, ukuzisebenzisa ngokwakho kwe-photovoltaic, izimo zamandla okusekela, ama-microgrid, kanye nezinhlelo zokusebenza ezingaphandle kwegridi.

Buka Ngini

Isixazululo EsikuGridi

Isixazululo se-Huijue On-Grid sihlanganisa amandla elanga, umoya, kanye nendawo yokugcina izinto kugridi ukuze kudluliselwe amandla ngendlela ephumelelayo kanye nokuphathwa kwamandla okusimeme. Isixazululo esixhunywe kugridi yi-Huijue Group (HJ Group) sihlanganisa imithombo yamandla esatshalaliswe (njenge-photovoltaic, amandla omoya, kanye nezinhlelo zokugcina amandla) kugridi yamandla yomphakathi. Ngokuxhuma kwegridi, imithombo yamandla esatshalaliswe ingafinyelela ukudluliselwa kwamandla okusebenzayo kanye nokusetshenziswa kwawo, okuhlinzeka ngokuguquguquka kanye nokusimama kokuphathwa kwamandla.

Buka Ngini

Cela ikhodi

Isevisi Engenazihibe Noma Kunini Uma Uyidinga lt

Sizibophezele ekunikezeni ukwesekwa okusheshayo, okuchwepheshile ukuze siqinisekise ukuthi izidingo zakho zamandla zihlala zihlangatshezwana nezinga eliphezulu lesevisi.

  •   Phendula phakathi kwamahora angu-24
  •   Amahora angu-24 ukwesekwa kwefoni
x
Xhumana nathi

Silapha ukuze siphendule imibuzo yakho futhi sikunikeze izixazululo zamandla ezifanelana kangcono nezidingo zakho.